Описание оборудования | |
---|---|
Inductive transmitter system | |
Nominal ratings | |
Operating voltage | 24 V DC ± 10 % |
Number of signal channels | 8 |
Signal transfer direction | from secondary side to primary side |
Reverse polarity protection | reverse polarity protected |
Current consumption | max. 1000 mA |
Functional safety related parameters | |
MTTFd | 245 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Switching state | 8 x LED, yellow |
Transfer indicator | LED, green |
Input | |
Number | 1 |
Input type | Activation input signal level: ?15V = active, ?3V inactive |
Input current | ? 1 mA |
Internal resistor | ? 15 k? |
Output | |
Output type | 1 Status output (high with proper transfer) and 8 Switch outputs PNP, NO. (switched high) , overload and short-circuit resistant |
Voltage drop | ? 2.5 V |
Load current | max. 50 mA |
Response time | ? 200 ms ( static operation , the transmission heads stand opposite to each other ) |
Compliance with standards and directives | |
Directive conformity | |
Standard conformity | |
Approvals and certificates | |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications | |
Degree of protection | IP20 |
Material | |
Installation | DIN rail mounting |
Mass | 106 g |
General information | |
Note | Maximum cable length between WIS module and WIS transmitter must not exceed 5 m. |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |