Attribute | 424A.1A... | 424A.6A... | 424A.7A... |
---|---|---|---|
Electrical data | |||
Polarity reversal protection | yes | ||
Output signal min. | – | 0.5 V DC | |
Output signal max. | – | 4.5 V DC | |
Output signal min. | 4 mA | – | |
Output signal max. | 20 mA | – | |
Output signal - centre position/zero position | – | 2.5 V DC | |
Output signal - centre position/zero position | 12 mA | – | |
Resolution | 0.1 ° | ||
EMC immunity (Norm) | EN 13309: 2010 EN ISO 14982:2009 DIN EN 12895:2001 | ||
EMC emission (Norm) | EN 13309: 2010 EN ISO 14982:2009 DIN EN 12895:2001 | ||
Operating voltage min. | 10 V DC | 4.5 V DC | 10 V DC |
Operating voltage max. | 30 V DC | 5.5 V DC | 30 V DC |
Current consumption | 18 mA | 8 mA | 10 mA |
Load resistance min. | – | 20000 Ohm | |
Load resistance max. | 250 Ohm | – | |
Short-circuit resistance to GND | yes | – | |
Short-circuit resistance to supply | yes | – | |
Temperature coefficient | typ. +- 220 ppm/K | typ. +- 245 ppm/K | |
Linearity error | typ. +-4,17 % | ||
Signal sequence | Standard CCW (optional CW) | ||
Signal update rate | 2000 Hz | ||
Outputs (quantity, type) | 1 | ||
Technology | Hall | ||
Angle measuring range | 30°...120 ° | ||
Outputs | 4...20mA | 0,5...4,5V ratiometric | 0,5...4,5V |
MTTF | 101 a | 225.7 a | 133 a |
Mechanical data | |||
Max. shaft load, axial | 50 N | ||
Max. shaft load, radial | 100 N | ||
Bearing | Ball bearing | ||
Mechanical stop | Optional | ||
Material information | |||
Housing material | PBT | ||
Environmental conditions | |||
Protection class | IP67 DIN EN 60529 | ||
Operating temperature min. | -40 °C | ||
Max. operating temperature | 85 °C | ||
Min. storage temperature | -40 °C | ||
Max. storage temperature | 85 °C | ||
Installation | |||
Torque |